Implement the security design principle of performance security in [Assignment: organization-defined systems or system components].
ID | Name | Description | D3FEND |
ID | Description |
Requirement | Rationale/Additional Guidance/Notes |
---|---|
The [spacecraft] shall integrate cyber related detection and responses with existing fault management capabilities to ensure tight integration between traditional fault management and cyber intrusion detection and prevention.{SV-DCO-1}{AU-6(4),IR-4,IR-4(1),RA-10,SA-8(21),SA-8(26),SC-3(4),SI-3,SI-3(10),SI-4(7),SI-4(13),SI-4(16),SI-4(24),SI-4(25),SI-7(7),SI-13} | The onboard IPS system should be integrated into the existing onboard spacecraft fault management system (FMS) because the FMS has its own fault detection and response system built in. SV corrective behavior is usually limited to automated fault responses and ground commanded recovery actions. Intrusion prevention and response methods will inform resilient cybersecurity design. These methods enable detected threat activity to trigger defensive responses and resilient SV recovery. |
The [spacecraft] shall be configured to provide only essential capabilities.{CM-6,CM-7,SA-8(2),SA-8(7),SA-8(13),SA-8(23),SA-8(26),SA-15(5)} |
ID | Name | Description |
---|