Gather FSW Development Information: Development Environment

Threat actors may gather information regarding the development environment for the victim SV's FSW. This information can include IDEs, configurations, source code, environment variables, source code repositories, code "secrets", and compiled binaries.

ID: CM0005
Sub-technique of:  REC-0006
Related Aerospace Threat IDs:  SV-CF-3 | SV-SP-10
Related MITRE ATT&CK TTPs:  T1592.002 | T1195.002
Tactic:
Created: 2022/10/19
Last Modified: 2022/10/19

Countermeasures

ID Name Description NIST Rev5 D3FEND ISO 27001
CM0001 Protect Sensitive Information Organizations should look to identify and properly classify mission sensitive design/operations information (e.g., fault management approach) and apply access control accordingly. Any location (ground system, contractor networks, etc.) storing design information needs to ensure design info is protected from exposure, exfiltration, etc. Space system sensitive information may be classified as Controlled Unclassified Information (CUI) or Company Proprietary. Space system sensitive information can typically include a wide range of candidate material: the functional and performance specifications, any ICDs (like radio frequency, ground-to-space, etc.), command and telemetry databases, scripts, simulation and rehearsal results/reports, descriptions of uplink protection including any disabling/bypass features, failure/anomaly resolution, and any other sensitive information related to architecture, software, and flight/ground /mission operations. This could all need protection at the appropriate level (e.g., unclassified, CUI, proprietary, classified, etc.) to mitigate levels of cyber intrusions that may be conducted against the project’s networks. Stand-alone systems and/or separate database encryption may be needed with controlled access and on-going Configuration Management to ensure changes in command procedures and critical database areas are tracked, controlled, and fully tested to avoid loss of science or the entire mission. Sensitive documentation should only be accessed by personnel with defined roles and a need to know. Well established access controls (roles, encryption at rest and transit, etc.) and data loss prevention (DLP) technology are key countermeasures. The DLP should be configured for the specific data types in question. AC-3(11) AC-4(23) AC-4(25) CM-12 CM-12(1) PM-11 PM-17 SA-3(1) SA-3(2) SA-4(12) SA-5 SA-9(7) SI-21 SI-23 SR-12 SR-7 A.8.4 A.8.11 A.8.10 A.8.33 7.5.1 7.5.2 7.5.3 A.5.37 A.8.10 A.5.22
CM0004 Development Environment Security In order to secure the development environment, the first step is understanding all the devices and people who interact with it. Maintain an accurate inventory of all people and assets that touch the development environment. Ensure strong multi-factor authentication is used across the development environment, especially for code repositories, as threat actors may attempt to sneak malicious code into software that's being built without being detected. Use zero-trust access controls to the code repositories where possible. For example, ensure the main branches in repositories are protected from injecting malicious code. A secure development environment requires change management, privilege management, auditing and in-depth monitoring across the environment. AC-20(5) AC-3(11) AC-3(13) AC-3(15) CA-8 CM-14 CM-2(2) CM-3(2) CM-3(7) CM-3(8) CM-4(1) CM-7(8) CM-7(8) CP-2(8) MA-7 PL-8(2) PM-30 PM-30(1) RA-3(1) RA-3(2) RA-5 RA-5(2) RA-9 SA-10 SA-11 SA-11(1) SA-11(2) SA-11(2) SA-11(4) SA-11(5) SA-11(5) SA-11(6) SA-11(7) SA-11(7) SA-11(8) SA-15 SA-15(3) SA-15(5) SA-15(7) SA-15(8) SA-3 SA-3(1) SA-3(2) SA-4(3) SA-4(5) SC-38 SI-2 SI-2(6) SR-1 SR-1 SR-11 SR-2 SR-2(1) SR-3 SR-3(2) SR-4 SR-4(1) SR-4(2) SR-4(3) SR-4(4) SR-5 SR-5 SR-5(2) SR-6 SR-6(1) SR-6(1) SR-7 A.8.4 A.8.9 A.8.9 A.8.31 A.5.30 4.4 6.2 7.5.1 7.5.2 7.5.3 10.2 A.8.8 A.5.22 A.5.2 A.5.8 A.8.25 A.8.31 A.8.33 A.8.28 A.8.9 A.8.28 A.8.30 A.8.32 A.8.29 A.8.30 A.8.28 A.5.8 A.8.25 A.8.28 A.6.8 A.8.8 A.8.32 5.2 5.3 7.5.1 7.5.2 7.5.3 A.5.1 A.5.2 A.5.4 A.5.19 A.5.31 A.5.36 A.5.37 A.5.19 A.5.20 A.5.21 A.8.30 A.5.20 A.5.21 A.5.21 A.8.30 A.5.20 A.5.21 A.5.23 A.8.29 A.5.22 A.5.22
CM0005 Ground-based Countermeasures This countermeasure is focused on the protection of terrestrial assets like ground networks and development environments/contractor networks, etc. Traditional detection technologies and capabilities would be applicable here. Utilizing resources from NIST CSF to properly secure these environments using identify, protect, detect, recover, and respond is likely warranted. Additionally, NISTIR 8401 may provide resources as well since it was developed to focus on ground-based security for space systems (https://nvlpubs.nist.gov/nistpubs/ir/2022/NIST.IR.8401.ipd.pdf). Furthermore, the MITRE ATT&CK framework provides IT focused TTPs and their mitigations https://attack.mitre.org/mitigations/enterprise/. Several recommended NIST 800-53 Rev5 controls are provided for reference when designing ground systems/networks. AC-1 AC-10 AC-11 AC-11(1) AC-12 AC-12(1) AC-14 AC-16 AC-16(6) AC-17 AC-17(1) AC-17(10) AC-17(2) AC-17(3) AC-17(4) AC-17(6) AC-17(9) AC-18 AC-18(1) AC-18(3) AC-18(4) AC-18(5) AC-19 AC-19(5) AC-2 AC-2(1) AC-2(11) AC-2(12) AC-2(13) AC-2(2) AC-2(3) AC-2(4) AC-2(9) AC-20 AC-20(1) AC-20(2) AC-20(3) AC-20(5) AC-21 AC-22 AC-3 AC-3(11) AC-3(13) AC-3(15) AC-3(4) AC-4 AC-4(23) AC-4(24) AC-4(25) AC-4(26) AC-4(31) AC-4(32) AC-6 AC-6(1) AC-6(10) AC-6(2) AC-6(3) AC-6(5) AC-6(8) AC-6(9) AC-7 AC-8 AT-2(4) AT-2(4) AT-2(5) AT-2(6) AT-3 AT-3(2) AT-4 AU-10 AU-11 AU-12 AU-12(1) AU-12(3) AU-14 AU-14(1) AU-14(3) AU-2 AU-3 AU-3(1) AU-4 AU-4(1) AU-5 AU-5(1) AU-5(2) AU-5(5) AU-6 AU-6(1) AU-6(3) AU-6(4) AU-6(5) AU-6(6) AU-7 AU-7(1) AU-8 AU-9 AU-9(2) AU-9(3) AU-9(4) CA-3 CA-3(6) CA-3(7) CA-7 CA-7(1) CA-7(6) CA-8 CA-9 CM-10(1) CM-11 CM-11(2) CM-11(3) CM-12 CM-12(1) CM-14 CM-2 CM-2(2) CM-2(3) CM-2(7) CM-3 CM-3(1) CM-3(2) CM-3(5) CM-3(7) CM-3(7) CM-3(8) CM-4 CM-5(1) CM-5(5) CM-6 CM-6(1) CM-6(2) CM-7 CM-7(1) CM-7(2) CM-7(3) CM-7(5) CM-7(8) CM-7(8) CM-7(9) CM-8 CM-8(1) CM-8(2) CM-8(3) CM-8(4) CM-9 CP-10 CP-10(2) CP-10(4) CP-2 CP-2(2) CP-2(5) CP-2(8) CP-3(1) CP-4(5) CP-8 CP-8(1) CP-8(2) CP-8(3) CP-8(4) CP-8(5) CP-9 CP-9(1) CP-9(2) CP-9(3) IA-11 IA-12 IA-12(1) IA-12(2) IA-12(3) IA-12(4) IA-12(5) IA-12(6) IA-2 IA-2(1) IA-2(12) IA-2(2) IA-2(5) IA-2(6) IA-2(8) IA-3 IA-3(1) IA-4 IA-4(9) IA-5 IA-5(1) IA-5(13) IA-5(14) IA-5(2) IA-5(7) IA-5(8) IA-6 IA-7 IA-8 IR-2 IR-2(2) IR-2(3) IR-3(3) IR-4 IR-4(1) IR-4(11) IR-4(11) IR-4(12) IR-4(13) IR-4(14) IR-4(3) IR-4(4) IR-4(6) IR-4(7) IR-4(8) IR-5 IR-5(1) IR-6 IR-6(1) IR-7 IR-7(1) MA-2 MA-3 MA-3(1) MA-3(2) MA-3(3) MA-4 MA-4(1) MA-4(3) MA-4(6) MA-4(7) MA-5(1) MA-6 MA-7 MP-2 MP-3 MP-4 MP-5 MP-5(4) MP-6 MP-6(3) MP-7 PE-3(7) PL-10 PL-11 PL-8 PL-8(1) PL-8(2) PL-9 PL-9 PM-11 PM-16(1) PM-17 PM-30 PM-30(1) PM-31 PM-32 RA-10 RA-3(1) RA-3(2) RA-3(2) RA-3(3) RA-3(4) RA-5 RA-5(10) RA-5(11) RA-5(2) RA-5(4) RA-5(5) RA-7 RA-9 RA-9 SA-10 SA-10(1) SA-10(7) SA-11 SA-11(2) SA-11(9) SA-15 SA-15(3) SA-15(7) SA-17 SA-2 SA-22 SA-3 SA-3(1) SA-3(2) SA-3(2) SA-4 SA-4(1) SA-4(10) SA-4(12) SA-4(2) SA-4(3) SA-4(5) SA-4(7) SA-4(9) SA-5 SA-8 SA-8(14) SA-8(15) SA-8(18) SA-8(21) SA-8(22) SA-8(23) SA-8(24) SA-8(9) SA-9 SA-9(1) SA-9(2) SA-9(6) SA-9(7) SC-10 SC-12 SC-12(1) SC-12(6) SC-13 SC-15 SC-16(2) SC-16(3) SC-18(1) SC-18(2) SC-18(3) SC-18(4) SC-2 SC-2(2) SC-20 SC-21 SC-22 SC-23 SC-23(1) SC-23(3) SC-23(5) SC-24 SC-28 SC-28(1) SC-28(11) SC-28(3) SC-3 SC-38 SC-39 SC-4 SC-45 SC-45(1) SC-45(1) SC-45(2) SC-49 SC-5 SC-5(1) SC-5(2) SC-5(3) SC-50 SC-51 SC-7 SC-7(10) SC-7(11) SC-7(12) SC-7(13) SC-7(14) SC-7(18) SC-7(21) SC-7(25) SC-7(29) SC-7(3) SC-7(4) SC-7(5) SC-7(5) SC-7(7) SC-7(8) SC-7(9) SC-8 SC-8(1) SC-8(2) SC-8(5) SI-10 SI-10(3) SI-10(6) SI-11 SI-14(3) SI-16 SI-19(4) SI-2 SI-2(2) SI-2(3) SI-2(6) SI-21 SI-3 SI-3 SI-3(10) SI-4 SI-4(1) SI-4(10) SI-4(11) SI-4(12) SI-4(14) SI-4(15) SI-4(16) SI-4(2) SI-4(20) SI-4(22) SI-4(23) SI-4(25) SI-4(4) SI-4(5) SI-5 SI-5(1) SI-6 SI-7 SI-7(1) SI-7(17) SI-7(2) SI-7(5) SI-7(7) SI-7(8) SR-1 SR-1 SR-10 SR-11 SR-11 SR-11(1) SR-11(2) SR-11(3) SR-12 SR-2 SR-2(1) SR-3 SR-3(1) SR-3(2) SR-3(2) SR-3(3) SR-4 SR-4(1) SR-4(2) SR-4(3) SR-4(4) SR-5 SR-5 SR-5(1) SR-5(2) SR-6 SR-6(1) SR-6(1) SR-7 SR-7 SR-8 SR-9 SR-9(1) 5.2 5.3 7.5.1 7.5.2 7.5.3 A.5.1 A.5.2 A.5.4 A.5.15 A.5.31 A.5.36 A.5.37 A.5.16 A.5.18 A.8.2 A.8.16 A.5.15 A.5.33 A.8.3 A.8.4 A.8.18 A.8.20 A.8.2 A.8.4 A.5.14 A.8.22 A.8.23 A.8.11 A.8.10 A.5.15 A.8.2 A.8.18 A.8.5 A.8.5 A.7.7 A.8.1 A.5.14 A.6.7 A.8.1 A.8.16 A.5.14 A.8.1 A.8.20 A.5.14 A.7.9 A.8.1 A.5.14 A.7.9 A.8.20 A.6.3 A.8.15 A.8.15 A.8.6 A.5.25 A.6.8 A.8.15 A.7.4 A.8.17 A.5.33 A.8.15 A.5.28 A.8.15 A.8.15 A.8.15 A.5.14 A.8.21 9.1 9.3.2 9.3.3 A.5.36 9.2.2 A.8.9 A.8.9 8.1 9.3.3 A.8.9 A.8.32 A.8.9 A.8.9 A.8.9 A.8.9 A.8.19 A.8.19 A.5.9 A.8.9 A.5.2 A.8.9 A.8.19 7.5.1 7.5.2 7.5.3 A.5.2 A.5.29 A.8.1 A.8.6 A.5.30 A.5.29 A.7.11 A.5.29 A.5.33 A.8.13 A.5.29 A.5.16 A.5.16 A.5.16 A.5.17 A.8.5 A.5.16 A.6.3 A.5.25 A.5.26 A.5.27 A.8.16 A.5.5 A.6.8 A.7.10 A.7.13 A.8.10 A.8.10 A.8.16 A.8.10 A.7.13 A.5.10 A.7.7 A.7.10 A.5.13 A.5.10 A.7.7 A.7.10 A.8.10 A.5.10 A.7.9 A.7.10 A.5.10 A.7.10 A.7.14 A.8.10 A.5.10 A.7.10 A.5.8 A.5.7 4.4 6.2 7.5.1 7.5.2 7.5.3 10.2 4.4 6.2 7.4 7.5.1 7.5.2 7.5.3 9.1 9.2.2 10.1 10.2 A.8.8 6.1.3 8.3 10.2 A.5.22 A.5.7 A.5.2 A.5.8 A.8.25 A.8.31 A.8.33 8.1 A.5.8 A.5.20 A.5.23 A.8.29 A.8.30 A.8.28 7.5.1 7.5.2 7.5.3 A.5.37 A.8.27 A.8.28 A.5.2 A.5.4 A.5.8 A.5.14 A.5.22 A.5.23 A.8.21 A.8.9 A.8.28 A.8.30 A.8.32 A.8.29 A.8.30 A.5.8 A.8.25 A.8.25 A.8.27 A.8.6 A.5.14 A.8.16 A.8.20 A.8.22 A.8.23 A.8.26 A.8.23 A.8.12 A.5.10 A.5.14 A.8.20 A.8.26 A.5.33 A.8.20 A.8.24 A.8.24 A.8.26 A.5.31 A.5.14 A.5.10 A.5.33 A.6.8 A.8.8 A.8.32 A.8.7 A.8.16 A.8.16 A.8.16 A.5.6 A.8.11 A.8.10 5.2 5.3 7.5.1 7.5.2 7.5.3 A.5.1 A.5.2 A.5.4 A.5.19 A.5.31 A.5.36 A.5.37 A.5.19 A.5.20 A.5.21 A.8.30 A.5.20 A.5.21 A.5.21 A.8.30 A.5.20 A.5.21 A.5.23 A.8.29 A.5.22 A.5.22

References