Adversaries seek a working map of the thermal architecture and its operating envelopes to anticipate stress points and plan timing for other techniques. Valuable details include passive elements (MLI, coatings, radiators, heat pipes/straps, louvers) and active control (survival and control heaters, thermostats, pumped loops), plus sensor placement, setpoints, deadbands, heater priority tables, and autonomy rules that protect critical hardware during eclipses and anomalies. Artifacts often come from thermal math models (TMMs), TVAC test reports, heater maps and harness drawings, command mnemonics, and on-orbit thermal balance procedures. When correlated with attitude constraints, payload duty cycles, and power budgets, this information lets a threat actor infer when components run close to limits, how safing responds to off-nominal gradients, and where power-thermal couplings can be exploited. Even small fragments, such as louver hysteresis or a heater override used for decontamination, can reveal opportunities to mask heating signatures or provoke nuisance safing.